3-24
PCZ1000A
Procedure for Connecting Units in Parallel
Parallel operation requires connection of a signal cable between the loads and a load
cable that connects to the equipment under test.
For the signal cable, always use the flat cable (PC01-PCZ1000A) available as an
option. Use load cables for the connection from the PCZ1000A to the equipment
under test.
Fig.3-9 Flat Cable for Parallel Operation, Available as an Option
Risk of electric shock
• Turn off the POWER switch when you are touching the load input
terminals, PARALLEL IN connector, or PARALLEL OUT connector.
Also, re-attach the load input terminal cover after connecting the
cables.
• Always fit the protective socket when not using the PARALLEL IN
connector or PARALLEL OUT connector.
• If the flat cable used for parallel operation becomes disconnected
during parallel or tracking operation, turn off the POWER switch on
each unit before reconnecting.
Risk of damage to the instrument
•
Take care not to get the PARALLEL IN
connector and
PARALLEL OUT
connector mixed up.
•
Ensure that the load cable is as short as possible with a sufficient cross-
section area for the current level being used.
• Note that the ammeter (RMS, peak) on the master unit will not display correctly
if the flat cable used for parallel operation becomes disconnected during parallel
or tracking operation.
• Ensure that the insulation on the load cable you use has good fire resistance.
• Ensure that the cables to the load input terminals on each PCZ1000A are as
similar in length as possible.
1
Turn off the POWER switch.
2
Connect the cables to the load input terminals.
Referring to the connection diagram in Fig.3-8, connect the cables to the load input
terminals on each unit (which must all be of the same model).
3
Connect the parallel operation connector.
Use the option flat cable (PC01-PCZ1000A) to connection between the PARALLEL
OUT and PARALLEL IN connectors on each unit.
WARNING
CAUTION
Содержание PCZ1000A
Страница 4: ...ii PCZ1000A This page is intentionally blank ...
Страница 14: ...xii PCZ1000A Front panel 18 17 Control panel Control panel 1 Display Display 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 17: ...General Description This chapter gives an overview and describes the features of the PCZ1000A ...
Страница 35: ...Operation This chapter describes each mode and function of the operation ...
Страница 82: ...5 4 PCZ1000A This page is intentionally blank ...
Страница 83: ...Specifications This chapter gives the specifications and dimensions of the PCZ1000A ...
Страница 88: ...6 6 PCZ1000A This page is intentionally blank ...
Страница 89: ...The appendix contains the basic operating modes operating range and troubleshooting Appendix ...
Страница 99: ......