3-18
PCZ1000A
Saving Preset Memory
This saves the limit value and range settings displayed on the front panel. The
example described below saves RSET:10
Ω
and range: H in preset memory A.
1
Press the R SET key.
2
Use the rotary knob to set the resistance limit to 10
Ω
.
3
Use the SHIFT + R SET (RANGE) key to set H range.
Example: RSET: 10
Ω
, Range: H
4
Press the MEM key.
"MEM<ABC>Save Mode" appears on the lower part of the front panel display.
5
Press the A, B or C key to save to one of the preset memories.
Example: Save in preset memory A.
6
Press the MEM or ESC key to end the save operation.
The display returns to its state prior to saving.
• To save the crest factor value in CC mode to memory, first set the crest factor
value and then press the I SET key to change to CC mode, then press the MEM
key followed by the A, B, or C key to save the value of current limit and crest
factor together.
8.49Ar12.0Ap 84.9V
-- RSET 10.000
·
H--
8.49Ar12.0Ap 84.9V
-- MEM<ABC>Save Mode
8.49Ar12.0Ap 84.9V
-- MEM<ABC>Save A --
Содержание PCZ1000A
Страница 4: ...ii PCZ1000A This page is intentionally blank ...
Страница 14: ...xii PCZ1000A Front panel 18 17 Control panel Control panel 1 Display Display 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 17: ...General Description This chapter gives an overview and describes the features of the PCZ1000A ...
Страница 35: ...Operation This chapter describes each mode and function of the operation ...
Страница 82: ...5 4 PCZ1000A This page is intentionally blank ...
Страница 83: ...Specifications This chapter gives the specifications and dimensions of the PCZ1000A ...
Страница 88: ...6 6 PCZ1000A This page is intentionally blank ...
Страница 89: ...The appendix contains the basic operating modes operating range and troubleshooting Appendix ...
Страница 99: ......