Keysight E1412A Digital Multimeter User Guide
cxciii
TRIGger
Multimeter Command Reference
Parameters
Comments
–
You can substitute decimal values for the
OFF
(“
0
”) and
ON
(“
1
”)
parameters.
–
The trigger delay is inserted between the trigger and each measurement.
–
If a trigger delay is specified using the
TRIGger:DELay <
period
>
command,
TRIG:DEL:AUTO
is turned
OFF
.
–
*RST
Condition:
TRIG:DEL:AUTO ON
Example
Disable Automatic Trigger Delay
TRIG:DEL:AUTO OFF
Disable automatic trigger delay.
Parameter Name Parameter Type
Range of Values
Default
Units
<
mode
>
boolean
OFF|0|ON|1
none
Default Trigger Delays for DC Voltage and DC Current (all ranges):
Integration Time
Trigger Delay
NPLC
1
1.5ms
NPLC <1
1.0ms
Default Trigger Delays for 2-Wire and 4-Wire Resistance:
Range
Trigger Delay
(For NPLC
1)
Trigger Delay
(For NPLC <1)
100
1.5ms
1.0ms
1k
1.5ms
1.0ms
10k
1.5ms
1.0ms
100k
1.5ms
1.0ms
1M
1.5ms
10ms
10M
100ms
100ms
100M
100ms
100ms
Default Trigger Delays for AC Voltage and AC Current (all ranges):