clxxxiv
Keysight E1412A Digital Multimeter User Guide
Multimeter Command Reference
[SENSe:]
–
The
OFF
parameter disables autozero. In this mode the multimeter takes
one zero measurement and subtracts it from all subsequent input signal
measurements prior to a change in function, range or integration time. A
new zero measurement is made following a change in function, range or
integration time. This mode increases measurement speed because a zero
measurement is not made for each input signal measurement.
–
Autozero
ONCE
issues an immediate zero measurement and can be used
to get an update on the zero measurement for a specific input signal
measurement. This helps to increase measurement time since you update
the zero reading without making zero measurements for every
measurement.
–
*RST
Condition:
ZERO:AUTO ON
(enables autozero mode)
Example
Disable Autozero
ZERO:AUTO OFF
Autozero disabled.
ZERO:AUTO?
[SENSe:]ZERO:AUTO?
queries the autozero mode. Returns one of the following
responses to the output buffer:
–
“
0
” (
OFF
or
ONCE
) if autozero is disabled or set for one time.
–
“
1
”
ON
if autozero is enabled.
Example
Query the Autozero Mode
ZERO:AUTO?
Queries the autozero mode.
enter statement
Enter response into computer.
Содержание E1412A
Страница 1: ...Keysight E1412A 6 1 2 Digit Multimeter User Manual and SCPI Programming Guide 75000 Series C ...
Страница 2: ......
Страница 6: ...vi ...
Страница 18: ...xviii Keysight E1412A Multimeter User Guide ...
Страница 208: ...ccviii Keysight E1412A Digital Multimeter User Guide Multimeter Command Reference SCPI Command Quick Reference ...
Страница 242: ......