Chapter 5
61
Starting (Triggering) Measurement and Waiting for Completion of Measurement
Starting (triggering) Measurement
5.
Startin
g (T
rigg
er
ing)
M
easur
em
ent
an
d
W
aiting
for
Comp
letion
o
f Me
asur
eme
nt
When the trigger system is started up using the following commands, it transitions to the
waiting for trigger state (a in
).
•
:INITiate[:IMMediate] on page 224
•
:INITiate:CONTinuous on page 224
(when executed with ON specified)
Waiting for trigger state (trigger event detect state)
The waiting for trigger state, when the instrument is triggered (a trigger is detected) or the
:TRIGger[:SEQ1][:IMMediate] command on page 298
is executed, transit to the
measurement state.
As shown in the table below, the instrument triggering method differs depending on which
trigger mode is set. To set up the trigger mode, use the
.
Figure 5-2
Transition flow from waiting for trigger state to measurement state
Measurement state (sequence operation state)
Measurement is performed in the measurement state. After transiting from
trigger state (trigger event detect state)”
to the measurement state, then wait for trigger
delay and source delay
.
When the measurement is finished, the state transitions to a
different state depending on the setup of the continuous activation of the trigger system (set
Trigger mode
Instrument triggering method
Internal trigger (Int)
The instrument is automatically triggered within itself.
External trigger (Ext)
The instrument is triggered when a trigger signal is input
through the Ext Trig terminal or the handler/scanner interface.
BUS trigger (Bus)
The instrument is triggered when the
is executed.
Manual trigger (Man)
The instrument is triggered when the [Trigger] key on the
front panel is pressed.
e4981ape0051
W aiting for T rig g er S tate
e xe c ute d
T o M e a sure m e nt S ta te
T rig g e r
D e te c te d
T rig g e r
:TRIG
T rig g e r S o u rc e S e t
(S e t w ith
:TRIG:SOUR
)
In te rn a l
E x te rn a l
B u s
M a n u a l
Содержание E4981A
Страница 2: ......
Страница 20: ...18 Chapter1 Making Effective Use of This Manual How To Use This Manual ...
Страница 60: ...58 Chapter4 Preparation for Accurate Measurement Executing Correction Using the Cable Correction Function ...
Страница 88: ...86 Chapter7 Sorting Based on Measured Result Comparator Function Sample Program ...
Страница 162: ...160 Chapter9 Measurement Applications Sample Programs Detecting Error Occurrence using SRQ HT Basic ...
Страница 376: ...374 AppendixE Error Messages Warning Messages WARNING ...
Страница 382: ......
Страница 383: ...This information is subject to change without notice Keysight Technologies 2008 2014 Edition 2 August 2014 E4981 90001 ...