FORM 100.50-NOM6
ISSUE DATE: 8/07/2017
2
WEIGHT (LBS)
FILTER OPTIONS
MODEL
050
051
060
061
2" Cleanable
0
0
0
0
2" Pleated
0
0
0
0
2" Carbon
0
0
0
0
Rigid Filter - 2" Throwaway - Only
0
0
0
0
Rigid Filter - 12" 60-65%
319
319
319
319
Rigid Filter - 12" 90-95%
319
319
319
319
Final Filters
305
305
305
305
ECONOMIZER / EXHAUST FAN / RETURN FAN OPTIONS
MODEL
050
051
060
061
Economizer
527
527
527
527
EXHAUST-RETURN FAN
050
051
060
061
Exhaust Fan Option
465
465
465
465
Return Fan Option
691
691
691
691
EXHAUST DAMPER
050
051
060
061
Exhaust Damper Barometric
36
36
36
36
Exhaust Damper Modulating
53
53
53
53
EXHAUST-RETURN FAN MOTOR
050
051
060
061
Exhaust Fan Motor - 5hp
87
87
87
87
Exhaust Fan Motor - 7.5hp
120
120
120
120
Exhaust Fan Motor - 10hp
144
144
144
144
Exhaust Fan Motor - 15hp
217
217
217
217
Return Fan Motor - 5 HP
174
174
174
174
Return Fan Motor - 7.5 HP
240
240
240
240
Return Fan Motor - 10 HP
288
288
288
288
Return Fan Motor - 15 HP
434
434
434
434
EXHAUST FAN VFD
050
051
060
061
Exhaust Fan VFD 5 - 10 HP
22
22
22
22
Exhaust Fan VFD 15 HP
51
51
51
51
CONDENSER GUARD OPTIONS
MODEL
050
051
060
061
Condenser Coil Guard (Wire)
64
64
64
64
Condenser Coil Guard Louvered Sheet Metal)
292
292
292
292
HEAT OPTIONS
MODEL
050
051
060
061
Electric Heat - 40kW (Max)
410
410
410
410
Electric Heat - 80kW (Max)
430
430
430
430
Electric Heat - 108kW (Max)
450
450
450
450
Electric Heat - 150kW (Max)
470
470
470
470
Electric Heat - 200kW (Max)
490
490
490
490
Electric Heat - 250kW (Max)
510
510
510
510
Gas Heat - 375 MBH (Max)
162
162
162
162
Gas Heat - 750 MBH (Max)
324
324
324
324
Gas Heat - 1125 MBH (Max)
486
486
486
486
Hot Water Coil
281
281
281
281
Steam Coil
202
202
202
202
TABLE 3 –
UNIT WEIGHTS - 050-061 MODELS (CONT'D)
Содержание 050
Страница 112: ...JOHNSON CONTROLS 112 FORM 100 50 NOM6 ISSUE DATE 8 07 2017 SECTION 6 USER INTERFACE SENSOR READINGS LD13017 ...
Страница 113: ...JOHNSON CONTROLS 113 SECTION 6 USER INTERFACE FORM 100 50 NOM6 ISSUE DATE 8 07 2017 6 ECONOMIZER EXHAUST LD13018 ...
Страница 114: ...JOHNSON CONTROLS 114 FORM 100 50 NOM6 ISSUE DATE 8 07 2017 SECTION 6 USER INTERFACE FANS LD13019 ...
Страница 115: ...JOHNSON CONTROLS 115 SECTION 6 USER INTERFACE FORM 100 50 NOM6 ISSUE DATE 8 07 2017 6 COOLING SETUP LD13020 ...
Страница 116: ...JOHNSON CONTROLS 116 FORM 100 50 NOM6 ISSUE DATE 8 07 2017 SECTION 6 USER INTERFACE COOLING STATUS LD13021 ...
Страница 117: ...JOHNSON CONTROLS 117 SECTION 6 USER INTERFACE FORM 100 50 NOM6 ISSUE DATE 8 07 2017 6 HEATING SETUP LD13022 ...
Страница 118: ...JOHNSON CONTROLS 118 FORM 100 50 NOM6 ISSUE DATE 8 07 2017 SECTION 6 USER INTERFACE HEATING STATUS LD13023 ...
Страница 119: ...JOHNSON CONTROLS 119 SECTION 6 USER INTERFACE FORM 100 50 NOM6 ISSUE DATE 8 07 2017 6 SYSTEM OPTIONS LD13024 ...
Страница 120: ...JOHNSON CONTROLS 120 FORM 100 50 NOM6 ISSUE DATE 8 07 2017 SECTION 6 USER INTERFACE OUTPUTS STATUS LD13025 ...
Страница 122: ...JOHNSON CONTROLS 122 FORM 100 50 NOM6 ISSUE DATE 8 07 2017 SECTION 6 USER INTERFACE GRAPHIC LD13027 CLOCK LD13028 ...
Страница 125: ...JOHNSON CONTROLS 125 SECTION 6 USER INTERFACE FORM 100 50 NOM6 ISSUE DATE 8 07 2017 6 ALARMS LD13031 ...