© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 2 6
Section 6
UBA™ Pro Series Universal Banknote Acceptor
Calibration and Testing
Entrance and Feed Motors
Simultaneous Operation Test
(Reverse)
To perform the Motor Operation Test of the Entrance
Motor and the Feed Motor in the reverse rotation at the
same time,
proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches as below (Figure 6-137).
3. Apply electrical power.
4. Confirm that the
Green
and
Red
Status LEDs are
lit.
5. Lift up on the Upper Guide Access Lever to open
the UBA Pro’s Cover
6. To start the Test, set the DIP Switch #8 to
OFF
7. The Rollers will start running in the reverse
direction when the Entrance and Feed Motors
function properly.
8. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
Figure 6-137
Simultaneous Speed Test (Reverse) 1
Figure 6-137
Entrance and Feed Motors
Simultaneous Speed Test (Reverse) 1
DIP Switches #2, #5, #6, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-138
Entrance and Feed Motors
Simultaneous Speed Test (Reverse) 2
Green Red
Figure 6-139
Simultaneous Speed Test (Reverse) 3
Figure 6-139
Entrance and Feed Motors
Simultaneous Speed Test (Reverse) 3
DIP Switch #8 OFF
ON
1
2
3
4
5
6
7
8
Figure 6-140
Entrance and Feed Motors
Simultaneous Speed Test (Reverse) 4
Содержание UBA Pro Series
Страница 8: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD v i THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 14: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i i THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 16: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i v THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 131: ...UBA Pro Series Universal Banknote Acceptor P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD...
Страница 132: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD UBA Pro Series Universal Banknote Acceptor Issue 4116 SME 01 00...