© 2020, JAPAN CASH MACHINE CO., LTD.
A - 1 0
Appendix A
UBA™ Pro Series Universal Banknote Acceptor
Troubleshooting
Calibration Error
When an error occurs during Calibration, the spe-
cific Error Codes will be shown in a pop-up win-
a
).
•
01-yyyy-yyyy-yyyy-yyyy (See Table A-8)
•
09-ZZ-ZZ-ZZ (See Table A-9)
•
03-00-00-xx (See Table A-10)
Figure A-1
Figure A-1
Calibration Error Code Pop-Up Screen
a
Table A-8
Calibration Program Error Codes
Calibration
Program
Error Code and
Causes
Solutions
Relative
Parts/Sensors
Validation Sensor
[D/A Value, non-Paper]
01-YYYY-YYYY-YYYY-YYYY
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
Line Sensor
Validation Sensor
with Paper
02-YYYY-YYYY-YYYY-YYYY
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
Line Sensor
Barcode Sensor
03-00-00-XX
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
Barcode Sensor
UV (Reflection) Sensor
with Paper
04-00-00-00
Calibration Program process
failed.
•
Check that a correct Reference Paper is placed in
a proper direction. (Refer to “Placing Reference
•
Check that a Reference Paper is not damaged or
dirty. (Refer “Reference Paper Handling” on
•
Check that the relative part is properly
assembled and/or Harness are connected.
•
Clean the relative Sensor. (Refer to “Cleaning
Procedure” on page 2-17.)
•
UV Sensor
NOTE: If the error is not resolved, change the relative part(s) and Sensor(s).
Calibration Program Error Codes
Table A-8 lists the various Error Code causes and solutions for the Calibration Program.
Содержание UBA Pro Series
Страница 8: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD v i THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 14: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i i THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 16: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i v THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 131: ...UBA Pro Series Universal Banknote Acceptor P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD...
Страница 132: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD UBA Pro Series Universal Banknote Acceptor Issue 4116 SME 01 00...