Calibration and Testing
UBA™ Pro Series Universal Banknote Acceptor
Section 6
Calibration
This section provides instructions for performing a
calibration of the UBA Pro Sensors.
When to Calibrate
Calibration should be performed when one of the
following five (5) conditions occur:
•
The Unit is disassembled or reassembled.
•
One of Sensors is removed or replaced.
•
The UBA Pro Main Board is removed or replaced.
•
Dirt adheres to the Sensors (See “Cleaning
•
The Banknote Acceptance Rate becomes drastically
degraded.
Placing Reference Paper
Perform the following steps to properly place a
selected Reference Paper (KS-101) into the UBA
Pro Unit.
1. Lift up on the Upper Guide Access Lever to open
the UBA Pro’s Cover (Figure 6-21
a
).
2. Slide the selected Reference Paper (Figure 6-21
b
) into the Unit until its Catch Edges evenly
touch both the left and right side of the Frame
A
).
3. Firmly close the Upper Guide (Figure 6-22
a
)
until it “clicks” in place, and ensure that both
sides are tightly closed and locked.
Sensor Calibration
To calibrate the UBA Pro sensors, proceed as
follows:
1. Remove electrical power from the UBA Pro Unit.
2. Set DIP Switches as below (Figure 6-23).
3. Connect the UBA Pro Unit to the PC.
4. Apply electrical power to the UBA Pro Unit.
5. The
Green
and
Red
Status LEDs will be lit.
6. Launch the “
JCM Tool Suite Standard Edition
”
Application.
7. Click and hold-down the “
Service Mode
” Pull-
Down Menu.
8. Select “
Sensor Adjustment
a
).
NOTE: Do not touch the Paper Surfaces on
either side of the KS-101 Reference Paper
Figure 6-20
Figure 6-20
KS-101 Reference Paper
KS-101
Paper
Surface
Figure 6-21
Placing Reference Paper 1
Figure 6-21
a
b
Slide In
NOTE: Place the Reference Paper upward so
the ID Sticker is visible; otherwise, calibration
will not be performed correctly.
A
ID Sticker
Figure 6-22
Figure 6-22
Placing Reference Paper 2
a
Click
Figure 6-23
Sensor Calibration 1
DIP Switch #8 ON
ON
1
2
3
4
5
6
7
8
NOTE: Refer to Figure 6-1 for the
necessary Tool and Harness
Connections and USB Cable Type
Requirements respectively.
Figure 6-24
Sensor Calibration 2
a
Содержание UBA Pro Series
Страница 8: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD v i THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 14: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i i THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 16: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD x i v THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 131: ...UBA Pro Series Universal Banknote Acceptor P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD...
Страница 132: ...P N 960 000211R_Rev A 2020 JAPAN CASH MACHINE CO LTD UBA Pro Series Universal Banknote Acceptor Issue 4116 SME 01 00...