SP-20000M-PMCL / SP-20000C-PMCL
- 95 -
(Bayer model only)
GainRawDigital
BlueAll
I Integer
R/W PGB
min
~
max
-4533 17713 0
PGB
=[Param.]<CR><
LF>
PGB?<CR><LF>
(Bayer model only)
GainAuto
I
Enumerat
ion
R/W AGC
0: Off
1: Continuous
2: Once
0
2
0
AGC
=[Param.]<CR><
LF>
AGC?<CR><LF>
BlackLevelRaw
All
I Integer
R/W BL
min
~
0
~
max
-256
255
0
BL
=[Param.]<CR><L
F>
BL?<CR><LF>
BlackLevelRaw
Tap1All
I Integer
R/W BL1
min
~
0
~
max
-512
511
0
BL1
=[Param.]<CR><
LF>
BL1?<CR><LF>
BlackLevelRaw
Tap1 Red
I Integer
R/W BLR1
min
~
0
~
max
-512
511
0
BLR1
=[Param.]<CR>
<LF>
BLR1?<CR><LF>
(Bayer model only)
BlackLevelRaw
Tap1 Blue
I Integer
R/W BLB1
min
~
0
~
max
-512
511
0
BLB1
=[Param.]<CR>
<LF>
BLB1?<CR><LF>
(Bayer model only)
BalanceWhiteA
uto
I
Enumerat
ion
R/W AWB
0: Off
2: Once
1: Continuous
0
2
0
AWB
=[Param.]<CR>
<LF>
AWB?<CR><LF>
(Bayer model only)
2.4.8 LUT Control
Name
Interfac
e
Acc
ess
Short
ASCII
Values
MIN
MAX
DEFAULT
Description
LUTValueRed
I Integer
R/W LUTR
Param 1: LUT index
Param 2:LUTdata(Min
~
Max)
(Bayer model only)
0
0
255
4095
γ=1
equival
ent
LUT*=[Param1],[Par
am2]<CR><LF>
LUT*?[Param1]<CR>
<LF>
LUTValueGreen I Integer
R/W LUTG
Param 1: LUT index
Param 2:LUTdata(Min
~
Max)
0
0
255
4095
LUTValueBlue
I Integer
R/W LUTB
Param 1: LUT index
Param 2:LUTdata(Min
~
Max)
(Bayer model only)
0
0
255
4095
2.4.9 Transport Layer Control
Name
Interfac
e
Acc
ess
Short
ASCII
Values
MIN
MAX
DEFAULT
Description
DeviceTapGeom
etry
I
Enumera
tion
R/W TAGM
3: Geometry_1X4_1Y
5: Geometry_1X8_1Y
3
5
5
TAGM
=[Param.]<CR>
<LF>
TAGM?<CR><LF>