SP-20000M-PMCL / SP-20000C-PMCL
- 22 -
5.4.10 Pulse Generator Inverter
Clear Source Signal can be have polarity inverted.
5.4.11 Pulse Generator setting parameters
Table - 12
Pulse Generator setting parameters
Display Name
Value
Clock Pre-scaler
1 to 4096
Pulse Generator Clock (MHzMHz)
[Pixel Clock:39.16 MHz]÷[Clock Pre-scaler]
Pulse Generator Selector
- Pulse Generator 0
- Pulse Generator 1
- Pulse Generator 2
- Pulse Generator 3
- Pulse Generator Length
1 to 1048575
- Pulse Generator Length (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator Length]
- Pulse Generator Frequency (Hz)
[
Pulse Generator Length (ms)
]
-1
- Pulse Generator Start Point
0 to 1048574
- Pulse Generator Start Point (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator Start Point]
- Pulse Generator End Point
1 to 1048575
- Pulse Generator End Point (ms)
(
[Clock Source]÷[Clock Pre-scaler]
)
-1
x [Pulse Generator End Point]
- Pulse Generator pulse-width (ms)
[ Pulse Generator End Point (ms)]
-
[ Pulse Generator Start Point (ms)]
- Pulse Generator Repeat Count
0 to 255
- Pulse Generator Clear Activation
Clear Mode for the Pulse Generators
- Off
- High Level
- Low level
- Rising Edge
- Falling Edge
- Pulse Generator Clear Sync Mode
- Async mode
- Sync mode
- Pulse Generator Clear Source
- Low
- High
- Frame Trigger Wait
- Frame Active
- Exposure Active
- Fval
- Lval
- PulseGenerator0
- PulseGenerator1
- PulseGenerator2
- PulseGenerator3
- TTL_In1
- CL_CC1_In
- Nand0 Out
- Nand1 Out
- Line 10 - TTL 2 In
- Line 11 - LVDS 1 In
- Pulse Generator Inverter(Polarity)
Pulse Generator Clear Inverter
- False
- True
Note:
1. If
Pulse Generator Repeat Count is set to “0”, the pulse generator works in free-running mode.
2. The output of the same pulse generator cannot be connected to Clear input.
3. If the Camera Link pixel clock is changed, the pixel clock of the pulse generator remains 39.16 MHz.