SP-20000M-PMCL / SP-20000C-PMCL
- 48 -
Table - 28
Calculation for the period which the exposure time is overlapped with previous trigger in
Continuous Trigger mode (3/3)
Tap
Geometry
Item
Binning
Vertical
Camera
Link
Pixel
Clock
Continuous trigger readout / exposure overlapped
period
Exposure Time value calculation formula
1X2-1Y
1Line
Control
Start
Exposure
Time
value
[Unit
:
us]
1 (Off)
80 MHz
ROUND([Frame Rate (Time)]
-
((([Height]
×
2618.54)
+
49865
-
2618.54
+
([Width]
÷
2))
÷
[Camera Link pixel clock:80MHz]
×
(10^6)))
60 MHz
ROUND([Frame Rate (Time)]
-
((([Height]
×
2637.25)
+
50223
-
2637.25
+
([Width]
÷
2))
÷
[Camera Link pixel clock:60MHz]
×
(10^6)))
2 (On)
80 MHz
ROUND([Frame Rate (Time)]
-
((([Height]
×
5237.09)
+
49865
-
2560
+
([Width]
÷
2))
÷
[Camera Link pixel clock:80MHz]
×
(10^6)))
60 MHz
ROUND([Frame Rate (Time)]
-
((([Height]
×
5274.49)
+
50223
-
2560
+
([Width]
÷
2))
÷
[Camera Link pixel clock:60MHz]
×
(10^6)))
1Line Contrl End
Exposure
Time
value
[Unit
:
us]
1 (Off) ,
2 (On)
80 MHz
ROUND([Frame Rate (Time)]
-
(49865
÷
[Camera Link pixel clock:80MHz]
×
(10^6))
60 MHz
ROUND([Frame Rate (Time)]
-
(50223
÷
[Camera Link pixel clock:60MHz]
×
(10^6))
When
overlapped,
Exposure
Time
effective
step
value
[Unit
:
us/step]
1 (Off)
80 MHz
ROUNDDOWN(2618.54
÷
[Camera Link pixel clock]
×
10^6)
60 MHz
ROUNDDOWN(2637.25
÷
[Camera Link pixel clock]
×
10^6)
2 (On)
80 MHz
ROUNDDOWN(5237.09
÷
[Camera Link pixel clock])
×
10^6
÷
2)
60 MHz
ROUNDDOWN(5274.49
÷
[Camera Link pixel clock])
×
10^6
÷
2)
Exposure
Start
Position
[Unit
:
Line]
1 (Off)
80 MHz
[Height]
-
1
-
(ROUNDDOWN(
( [Exposure Time]
-
[1Line Control Start Exposure Timevalue] )
×
(10^-6)
×
[Camera Link pixel clock:80MHz]
÷
2618.54))
60 MHz
[Height]
-
1
-
(ROUNDDOWN(
( [Exposure Time]
-
[1Line Control Start Exposure Time value] )
×
(10^-6)
×
[Camera Link pixel clock:80MHz]
÷
2637.25))
2 (On)
80 MHzz
[Height]
-
0.5
-
(ROUNDDOWN(
( [Exposure Time]
-
[1Line Control Start Exposure Time value] )
×
(10^-6)
×
[Camera Link pixel clock:80MHz]
÷
5237.09)
÷
2)
60 MHz
[Height]
-
0.5
-
(ROUNDDOWN(
( [Exposure Time]
-
[1Line Control Start Exposure Time value] )
×
(10^-6)
×
[Camera Link pixel clock:60MHz]
÷
5274.49)
÷
2)
Exposure Time
Max value
1 (Off) ,
2 (On)
80 MHz
ROUNDDOWN([Frame Rate (Time)]
-
(41200
÷
[Camera Link pixel
clock:80MHz]
×
10^6))
60 MHz
ROUNDDOWN([Frame Rate (Time)]
-
(41200
÷
[Camera Link pixel
clock:60MHz]
×
10^6))