SP-20000M-PMCL / SP-20000C-PMCL
- 55 -
7.5.4 Calculation formula for the minimum trigger interval if Trigger Overlap is Readout
Table - 36
Minimum Trigger Interval Calculation (If
EPS Trigger/ Trigger Overlap is Readout)
Camera Settings
EPS Trigger / Trigger Overlap = Readout
Minimum Trigger Interval calculation formula
[Unit
:
us]
Tap
Geometry
Camera
Link
Clock
Binning
Vertical
1X8-1Y
80 MHz
1 (Off)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
266
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)× 654.63)
-
654.63
+
([Width]÷8))÷80MHz×10^6)+331
(2) If [Exposure Time] value is more than 1Frame
=
266
+
[Exposure Time]
2 (On)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
266
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)×1309.27)
-
640
+
([Width]÷8))÷80MHz×10^6)+331
(2) If [Exposure Time] valueis more than 1Frame
=
266
+
[Exposure Time]
60 MHz
1 (Off)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
353
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)× 659.31)
-
659.31
+
([Width]÷8))÷60MHz×10^6)+441
(2) If [Exposure Time] value is more than 1Frame
=
353
+
[Exposure Time]
2 (On)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
353
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)×1318.61)
-
1318.61
+
([Width]÷8))÷60MHz×10^6)+441
(2) If [Exposure Time] value is more than 1Frame
=
353
+
[Exposure Time]
Note: When Trigger Overlap is set to Readout, if the trigger interval is set more than the period seecified in the above
table, the exposure operation may not be activated and the video may be disturbed.
Camera Settings
EPS Trigger / Trigger Overlap = Readout
Minimum Trigger Interval calculation formula
[Unit
:
us]
Tap
Geometry
Camera
Link
Clock
Binning
Vertical
1X4-1Y
80 MHz
1 (Off)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
266
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)×1309.27)
-
1309.27
+
([Width]÷4))÷80MHz×10^6)+339
(2) If [Exposure Time] value is more than 1Frame
=
266
+
[Exposure Time]
2 (On)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
266
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)×2618.53)
-
1280
+
([Width]÷4))÷80MHz×10^6)+339
(2) If [Exposure Time] value is more than 1Frame
=
266
+
[Exposure Time]
60 MHz
1 (Off)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
353
(1) If [Exposure Time]value is less than 1Frame
=
ROUND(((([Height]
+
1)×1318.61)
-
1318.61
+
([Width]÷4))÷60MHz×10^6)+452
(2) If [Exposure Time] value is more than 1Frame
=
353
+
[Exposure Time]
2 (On)
At the condition of [Expousre Time Max]
≦
[Trigger Period]
-
353
(1) If [Exposure Time] value is less than 1Frame
=
ROUND(((([Height]
+
1)×2637.23)
-
1280
+
([Width]÷4))÷60MHz×10^6)+452
(2) If [Exposure Time] value is more than 1Frame
=
353
+
[Exposure Time]