7.6 Trigger width mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer
exposure times are supported. Additional settings determine if the trigger pulse can be
accepted during the exposure period.
Basic settings to use this mode
Trigger Mode = ON
Expsoure Mode = Trigger Width
Table - 41
Minimum trigger interval (Trigger Overlap = Readout)
Readout Mode
Time (Min. Trigger Period)
1x8 – 1Y
1x4 – 1Y
1X2 – 1Y
80 MHz
60 MHz
80 MHz
60 MHz
80 MHz
60 MHz
Full
≧
31.761 ms
≧
42.648 ms
≧
63.200 ms
≧
84.864 ms
≧
126.389 ms
≧
169.719 ms
ROI Center 2/3
≧
21.287 ms
≧
28.582 ms
≧
42.252 ms
≧
56.734 ms
≧
84.492 ms
≧
113.457 ms
ROI Center 1/2
≧
16.050 ms
≧
21.550 ms
≧
31.777 ms
≧
42.669 ms
≧
63.544 ms
≧
85.327 ms
ROI Center 1/4
≧
8.195 ms
≧
11.001 ms
≧
16.066 ms
≧
21.571 ms
≧
32.121 ms
≧
43.131 ms
ROI Center 1/8
≧
4.267 ms
≧
5.726 ms
≧
8.211 ms
≧
11.022 ms
≧
16.410 ms
≧
22.033 ms
V Binning ON (Full)
(Note1)
≧
31.770 ms
≧
42.658 ms
≧
63.216 ms
≧
84.887 ms
≧
126.423 ms
≧
169.764 ms
Note1
:
SP-20000M-PMCL only