SP-20000M-PMCL / SP-20000C-PMCL
- 30 -
6.3.2 Vertical timing
In Continuous Trigger operation, the output through the Camera Link interface is as follows.
However, if 80-bit (1X8-1Y, 10-bits) configuration is set, DVAL and Exposure Active
(JAI CUSTOM) are not output through Camera Link “Spare” bit because this port is used
for data output.
The SP-20000-PMCL can support H-Binning and V-Binning functions, but the frame rate is
not increased.
FVAL
LVAL
DVAL
DATA
Exposure
Active
(Camera Link
“
Spare
”
bit)
Exposure time (Min)
FVAL Active (A)
(B)
(C) V-Offset
0 Line
DVAL Active (A)
(F) Exposure End to FVAL Active Start
(E) Exposure time (Max)
(D)
Fig. 16 Vertical timing