SP-20000M-PMCL / SP-20000C-PMCL
- 27 -
Table – 14 Continuous trigger horizontal timing
Camera Settings
(a)
(b)
(c)
(d)
T
a
p
G
e
o
m
e
tr
y
C
a
m
e
ra
L
in
k
P
ix
e
l
C
lo
c
k
ROI
Binning
LVAL
Active
LVAL
Non-Active
H-Offset
Exposure
Active Start
to
LVAL
Active Start
Step
(Typ.)
Width
Offset
X
Height
Offset
Y
Horiz
ontal
Verti
cal
[Unit:
Clock]
[Unit:
Clock]
[Unit:
Clock]
[Unit:
Camera Link Clock]
1X8
-1Y
80M
Hz
5120
0
3840
0
1
(Off)
1
(Off)
640
14
~
15
0
53
8
5120
0
1920
0
1
(Off)
2
(On)
640
669
~
670
0
53
or
707
8
2560
0
3840
0
2
(On)
1
(Off)
320
334
~
335
0
53
8
2560
0
1920
0
2
(On)
2
(On)
320
989
~
990
0
53
or
707
8
60M
Hz
5120
0
3840
0
1
(Off)
1
(Off)
640
19
~
20
0
53
10
5120
0
1920
0
1
(Off)
2
(On)
640
678
~
679
0
53
or
713
10
2560
0
3840
0
2
(On)
1
(Off)
320
339
~
340
0
53
10
2560
0
1920
0
2
(On)
2
(On)
320
998
~
999
0
53
or
713
10
1X4
-1Y
80M
Hz
5120
0
3840
0
1
(Off)
1
(Off)
1280
29
~
30
0
650
16
5120
0
1920
0
1
(Off)
2
(On)
1280
1339
~
1340
0
650
or
1959
16
2560
0
3840
0
2
(On)
1
(Off)
640
669
~
670
0
650
16
2560
0
1920
0
2
(On)
2
(On)
640
1979
~
1980
0
650
or
1959
16
60M
Hz
5120
0
3840
0
1
(Off)
1
(Off)
1280
38
~
39
0
653
22
5120
0
1920
0
1
(Off)
2
(On)
1280
1357
~
1358
0
653
or
1972
22
2560
0
3840
0
2
(On)
1
(Off)
640
678
~
679
0
653
22
2560
0
1920
0
2
(On)
2
(On)
640
1997
~
1998
0
653
or
1972
22
1X2
-1Y
80M
Hz
5120
0
3840
0
1
(Off)
1
(Off)
2560
58
~
59
0
1290
33
5120
0
1920
0
1
(Off)
2
(On)
2560
2677
~
2678
0
1290
or
3909
33
2560
0
3840
0
2
(On)
1
(Off)
1280
1339
~
1340
0
1290
33
2560
0
1920
0
2
(On)
2
(On)
1280
3957
~
3958
0
1290
or
3909
33
60M
Hz
5120
0
3840
0
1
(Off)
1
(Off)
2560
77
~
78
0
1301
44
5120
0
1920
0
1
(Off)
2
(On)
2560
2714
~
2715
0
1301
or
3939
44
2560
0
3840
0
2
(On)
1
(Off)
1280
1357
~
1358
0
1301
44
2560
0
1920
0
2
(On)
2
(On)
1280
3994
~
3995
0
1301
or
3939
44
Note:
1. In 1X8-1Y, 10-bit setting (80-bit Configuration), DVAL output port is used for data output and therefore, DVAL is not output through
Camera Link interface.
2. In the SP-20000-PMCL, the horizontal frequency is not doubled even if horizontal binning is ON.
3. In the SP-20000-PMCL, the horizontal frequency is 1/2 if vertical binning is ON. And if vertical binning is ON, the invalid data is output
in non-active range (H-offset range) of DVAL during LVAL being active.
4. H-Offset
:
Duration between LVAL Active Start and DVAL Active Start.
5. The phase of Exposure Active is described based on using the output at Camera Link Spare bit as the reference.
6. If the next exposure is done while the image of V-Binnig On is read out, the exposure control is increased or decreased by 0.5 line unit.
7. “d” ExposureActive Start to LVALActiveStart may have 1 clock difference due to the jitter in LVALNonActive period.