SP-20000M-PMCL / SP-20000C-PMCL
- 32 -
Table – 18 Continuous trigger vertical timing (2/2)
Camera Settings
(E)
(F)
T
a
p
G
e
o
m
e
tr
y
C
a
m
e
ra
L
in
k
P
ix
e
l C
lo
c
k
Frame
Rate
(Typ.)
ROI
Binning
Frame
Rate
Exposure
Time
(Max.)
Exposure
End
to
FVAL
Active
Start
Wi
d
th
O
ffs
e
t
X
H
e
ig
h
t
O
ffs
e
t
Y
H
o
riz
o
n
ta
l
V
e
rti
c
a
l
Time
[Unit: Hz]
[Unit: us]
[Unit: Line]
[Unit: us]
1X8-
1Y
80
MHz
33333
5120
0
3840
0
1
(Off)
1
(Off)
30.000
ROUNDDOWN(
[Frame Rate (Time)] -
(20600clk ÷ 80 ))
= 33075
39.10
319.96
5120
0
1920
0
1
(Off)
2
(On)
20.05
328.15
2560
0
3840
0
2
(On)
1
(Off)
39.10
319.96
2560
0
1920
0
2
(On)
2
(On)
20.05
328.15
60
MHz
44444
5120
0
3840
0
1
(Off)
1
(Off)
22.500
ROUNDDOWN(
[Frame Rate (Time)] -
(20600clk ÷ 60 ))
= 44100
39.10
429.68
5120
0
1920
0
1
(Off)
2
(On)
20.05
440.68
2560
0
3840
0
2
(On)
1
(Off)
39.10
429.68
2560
0
1920
0
2
(On)
2
(On)
20.05
440.68
1X4-
1Y
80
MHz
66666
5120
0
3840
0
1
(Off)
1
(Off)
15.000
ROUNDDOWN(
[Frame Rate (Time)] -
(20600clk ÷ 80 ))
= 66408
20.05
328.15
5120
0
1920
0
1
(Off)
2
(On)
10.53
344.51
2560
0
3840
0
2
(On)
1
(Off)
20.05
328.15
2560
0
1920
0
2
(On)
2
(On)
10.53
344.51
60
MHz
88888
5120
0
3840
0
1
(Off)
1
(Off)
11.250
ROUNDDOWN(
[Frame Rate (Time)] -
(20600clk ÷ 60 ))
= 88544
20.05
440.67
5120
0
1920
0
1
(Off)
2
(On)
10.53
462.63
2560
0
3840
0
2
(On)
1
(Off)
20.05
440.67
2560
0
1920
0
2
(On)
2
(On)
10.53
462.63
1X2-
1Y
80
M Hz
133333
5120
0
3840
0
1
(Off)
1
(Off)
7.500
ROUNDDOWN(
[Frame Rate (Time)] -
(41200clk ÷ 80 ))
= 132818
20.05
656.20
5120
0
1920
0
1
(Off)
2
(On)
10.52
688.93
2560
0
3840
0
2
(On)
1
(Off)
20.05
656.20
2560
0
1920
0
2
(On)
2
(On)
10.52
688.93
60
MHz
177777
5120
0
3840
0
1
(Off)
1
(Off)
5.625
ROUNDDOWN(
[Frame Rate (Time)] -
(41200clk ÷ 60 ))
= 177090
20.05
881.22
5120
0
1920
0
1
(Off)
2
(On)
10.52
925.17
2560
0
3840
0
2
(On)
1
(Off)
20.05
881.22
2560
0
1920
0
2
(On)
2
(On)
10.52
925.17
Note:
1. As the frame rate of the SP-20000-PMCL is 1 µs duration per 1 step, the above FVAL
Non-Active conversion may have certain
tolerance.
2. In the SP-20000-PMCL, the horizontal frequency is not doubled even if horizontal binning is used. The frame rate is not increased.
3. In the SP-20000-PMCL, the horizontal frequency is 1/2 if vertical binning is used. Therefore, if the height is 1/2, the vertical frequency
is not doubled.
4. In the SP-20000-
PMCL, the frame rate can be changed by 1 µs unit. In the above table, “B” FVAL Non-Active duration is
varied.
5. V-Offset
:
The duration between FVAL Active Start and 1st LVAL Active Start