6.3.3 ROI (Region Of Interest)
In the SP-20000-PMCL, a subset of the image can be output by setting Width, Height, Offset-X,
and Offset-Y. If the height is decreased, the number of lines read out is decreased and as the
result, the frame rate is increased. However, in the horizontal directon, the horizontal
frequency is not changed if the width is decreased. In the SP-20000-PMCL, the minimum width
is “8” and minimum height is “2”.
]
Note: Binning is available only for
SP-20000M-PMCL.
Binning can be used in horizontal,
vertical, or both directions.
Fig. 17
Setting example ( No binning)
Fig.18
Setting example (Binning)
Setting example (1)
Binning Horizontal = 1
Binning Vertical = 1
Mirroring = Off
Setting example (2)
Binning Horizontal = 2
Binning Vertical = 2
Mirroring = Off
OffsetX
OffsetY
Height
Width
2560 Width Max
19
20
H
ei
gh
t
M
ax
Readout area
OffsetX
Width
OffsetY
Height
Width
5120 Width Max
3
84
0
H
ei
gh
t
M
ax
Readout area