Содержание 10 Series

Страница 1: ......

Страница 2: ...2 4 Display 13 5 Icons 14 6 Indication sound vibration light 15 7 Battery charging 15 8 Firmware update 16 9 Menu usage 17 10 Device settings 18 Selecting units of measurement 19 Count rate alarm leve...

Страница 3: ...Chapter I...

Страница 4: ...tion automatic data storage in the instrument s memory accumulated dose monitoring quick search for radiation sources two channel alarm signaling of radiation danger and changes in the radiation situa...

Страница 5: ...strument Please read the instructions to obtain reliable results 1 2 Device design Design elements controls and indications controls and indications personal radiation detector Radiacode 10X series 1...

Страница 6: ...update period time for a level of random error 15 with natural radiation background 0 08 Sv h 0 1 1000 uSv h 15 0 5 s 34 s Accumulated dose assessment range 0 10 Sv Non volatile memory registration vo...

Страница 7: ...echnical requirements to the mobile device The device works with tablets or smartphones with minimum system requirements Android operating system version 6 0 and higher The device works with iPhone an...

Страница 8: ...Chapter II...

Страница 9: ...load process may lead to a malfunction of the device which can only be fixed by a certified service center FCC warning Federal Communications Commission FCC Statement This device complies with part 15...

Страница 10: ...Ltd Safety precautions and warnings RF exposure statement This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment The device is installed and operated wit...

Страница 11: ...Chapter III...

Страница 12: ...nection to an Android smartphone is also possible via USB OTG When connected to a computer or smartphone the accumulated data are transferred to an external device and the newly received data are tran...

Страница 13: ...ess of the round button is used to to lock the swing buttons return from the main menu to the display mode confirm selection of the highlighted menu item toggle the selection options to turn off the a...

Страница 14: ...round button and hold it down for three seconds The device can be switched off via the menu To turn on the instrument press and hold the round button until the instrument turns on at least 3 seconds...

Страница 15: ...on conditions backlight time backlight brightness and image orientation are set via the menu section Settings The display is used to show instrument status graphical dose rate level control menu setti...

Страница 16: ...u enter by long pressing the round button the sections are indicated by icons and text Settings Instrument settings menu Spectrum Display of the energy spectrum of radiation Monitor Display the curren...

Страница 17: ...he glowing of the blue indicator 18 in the general view If the device is turned on then the screen displays the icon 3 in the general view At the end of the charging procedure the blue indicator will...

Страница 18: ...ce and confirm by pressing the OK button confirm the firmware update of the instrument wait for the update process to complete Attention Do not turn off the instrument and do not disconnect the USB ca...

Страница 19: ...f the instrument settings Item About device is used to obtain information about the instrument number and firmware and bootloader versions At all levels the menu is arranged in a cyclical fashion For...

Страница 20: ...the focus to Measurement units Short press the round button to move to Measurement units Short presses on the round button to select dose rate measurement units Sv Sievert or R Roentgen Short presses...

Страница 21: ...ct Enter or Esc Long press the round button to confirm your selection This and deeper menu levels can be exited via Back and Menu quit or go to Alarm 2 Short press the round button to move to Alarm 2...

Страница 22: ...ge the value of the selected digit Set all digits Short presses on the round button to select Enter or Esc Long press the round button to confirm your selection This and deeper menu levels can be exit...

Страница 23: ...to Alarm 1 Short press the round button to select the desired digit of the threshold value Short presses on the up down swing buttons to change the value of the selected digit Set all digits Short pre...

Страница 24: ...minutes The screen backlight can be disabled completely allowed to be unconditionally turned on by pressing the buttons or by pressing the button in case of insufficient light level By default the dev...

Страница 25: ...us to Rotate Short press the round button to select the screen orientation Auto Right or Left To return to the previous level briefly press the up down swing buttons to move the focus to Back Briefly...

Страница 26: ...arm 1 screen backlight Alarm 1 screen backlight Out of scale screen backlight In the menu you can select the operation mode of sound light and vibration alarms Separate permissions to play alarm sound...

Страница 27: ...the up down swing buttons to move the focus to the Buttons Short press the up down swing buttons to move the focus to Buttons or Vibro Short press the round button to select the desired response type...

Страница 28: ...1 or Alarm 2 Press the round button briefly to confirm your selection Short press the up down swing buttons to move the focus to Sound or Vibration Short press the round button to select On or Off To...

Страница 29: ...o the previous level or exit the menu briefly press the up down swing buttons to move the focus to Back or Menu quit Briefly press the round button to confirm your selection 3 10 9 Time settings When...

Страница 30: ...provides an item for resetting the instrument to its original factory settings Briefly press the up down swing buttons to move the focus to the item Factory settings Press the round button briefly to...

Страница 31: ...ew of the photon gamma and X ray radiation energy spectrum In the Spectrum display mode the screen shows state panel from top energy spectrum of photon gamma and X ray radiation The upper part of the...

Страница 32: ...n the radiation situation the averaging continues in order to increase the reliability of the estimation Statistical error in the Monitor mode is maintained at the level not more than 15 for the confi...

Страница 33: ...registered quanta clicks Setting alarm thresholds Two alarm thresholds for the dose rate level can be set using the menu When the dose rate alarm threshold level is exceeded a pulsating sign will be d...

Страница 34: ...de is available via the buttons o long pressing the lower button resets the value of the accumulated dose o long pressing on the upper button of the swing turns on and off the sound indication Setting...

Страница 35: ...rol in this mode is available via buttons o a short press on the upper swing button increases the averaging time o a short press on the lower swing button decreases the averaging time o long press on...

Страница 36: ...ale Exceeding the upper threshold by count rate leads to unreliability of dose rate estimation In this case the upper threshold for dose rate is also considered to be exceeded If any of the alarm thre...

Страница 37: ...splays the message Alarms and icons of maximum alarm levels reached from the moment the buttons are locked to the current moment of time one icon for each source By long pressing the round button the...

Страница 38: ...Chapter IV...

Страница 39: ...e To pair with your smartphone install the app on your smartphone Radiacode available at link https space radiacode com and GooglePlay or use the QR code A detailed description of the application inte...

Страница 40: ...Chapter V...

Страница 41: ...Radiacode The program is available for downloading at https space radiacode com With the help of the program Radiacode you can transfer the data to a computer view it and manage personal radiation de...

Страница 42: ...se rate alarm 20 Firmware 15 Firmware update 15 icons 13 info 33 Language 27 Language selection 27 light 14 long press 11 16 menu 16 menu usage 16 menu use 16 off 12 on 12 PC 39 pressing 11 16 Reset 2...