SP-20000M-PMCL / SP-20000C-PMCL
- 51 -
7.4. Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)
This is used for applications which do not require triggering. In this mode, the video signal for
the auto-iris lens is available.
For the video timing, refer to chapter 6.3.
Table – 33 Minimum interval
Readout Mode
Time (Min. Trigger Period)
1x8 – 1Y
1x4 – 1Y
1X2 – 1Y
80 MHz
60 MHz
80 MHz
60 MHz
80 MHz
60 MHz
Full
33.333 ms
44.444 ms
66.666 ms
88.888 ms
133.333 ms
177.777 ms
ROI Center 2/3
22.222 ms
29.629 ms
44.444 ms
59.259 ms
88.889 ms
118.518 ms
ROI Center 1/2
16.667 ms
22.222 ms
22.222 ms
44.444 ms
66.667 ms
88.889 ms
ROI Center 1/4
8.428 ms
11.318 ms
16.826 ms
22.636 ms
33.713 ms
45.272 ms
ROI Center 1/8
4.500 ms
6.043 ms
9.001 ms
12.087 ms
18.002 ms
24.174 ms
V Binning ON (Full)
(Note 1)
33.333 ms
44.444 ms
66.666 ms
88.888 ms
133.333 ms
177.777 ms
Note 1: SP-20000M-PMCL only
7.5. Timed (EPS) mode
This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. An additional setting determines if the trigger pulse can be accepted during
the exposure period.
Basic settings to use this mode
Trigger Mode = ON
Exposure Mode = Timed
Trigger Option: OFF
Table - 34 Trigger minimum interval
(Trigger Overlap = Readout)
Readout Mode
Time (Min. Trigger Period)
1x8 – 1Y
1x4 – 1Y
1X2 – 1Y
80 MHz
60 MHz
80 MHz
60 MHz
80 MHz
60 MHz
Full
≧
31.761 ms
≧
42.648 ms
≧
63.200 ms
≧
84.864 ms
≧
126.389 ms
≧
169.719 ms
ROI Center 2/3
≧
21.287 ms
≧
28.582 ms
≧
42.252 ms
≧
56.734 ms
≧
84.492 ms
≧
113.457 ms
ROI Center 1/2
≧
16.050 ms
≧
21.550 ms
≧
31.777 ms
≧
42.669 ms
≧
63.544 ms
≧
85.327 ms
ROI Center 1/4
≧
8.195 ms
≧
11.001 ms
≧
16.066 ms
≧
21.571 ms
≧
32.121 ms
≧
43.131 ms
ROI Center 1/8
≧
4.267 ms
≧
5.726 ms
≧
8.211 ms
≧
11.022 ms
≧
16.410 ms
≧
22.033 ms
V Binning ON (Full)
(Note 1)
≧
31.770 ms
≧
42.658 ms
≧
63.216 ms
≧
84.887 ms
≧
126.423 ms
≧
169.764 ms
Note1
:
SP-20000M-PMCL only
Note2
:
If Trigger Overlap is OFF, the accumulation time is added to the above table.