7.6.3 Minimum trigger interval calculation formula (Trigger Overlap = OFF)
Table – 42 Minimum trigger interval calculation formula (Trigger Overlap = OFF)
Camera Settings
Trigger Width / Trigger Overlap = Off
Minimum Trigger interval calculation formula
[Unit
:
us]
Tap
Geometry
Camera
Link
Pixel
Clock
Binning
Vertical
1X8-1Y
80 MHz
1
(Off)
=
ROUND(((([1)×654.63) − 654.63 + ([Width]÷8) )
÷ 80MHz x 10^6) +321+ [Trigger Pulse Width:10us
~
]
2
(On)
=
ROUND(((([1)×1309.27) − 640 + ([Width]÷8) )
÷ 80MHz x 10^6) + 321 + [Trigger Pulse Width:10us
~
]
60 MHz
1
(Off)
=
ROUND(((([1)×659.31) − 659.31 + ([Width]÷8) )
÷ 60MHz x 10^6) + 431 + [Trigger Pulse Width:10us
~
]
2
(On)
=
ROUND(((([1)×1318.61) − 640 + ([Width]÷8) )
÷ 60MHz x 10^6) + 431 + [Trigger Pulse Width:10us
~
]
1X4-1Y
80 MHz
1
(Off)
=
ROUND(((([1)×1309.27) − 1309.27 + ([Width]÷4) )
÷ 80MHz x 10^6) + 329 + [Trigger Pulse Width:10us
~
]
2
(On)
=
ROUND(((([1)×2618.53) − 1280 + ([Width]÷4) )
÷ 80MHz x 10^6) + 329 + [Trigger Pulse Width:10us
~
]
60 MHz
1
(Off)
=
ROUND(((([1)×1318.61) − 1318.61 + ([Width]÷4) )
÷ 60MHz x 10^6) + 442 + [Trigger Pulse Width:10us
~
]
2
(On)
=
ROUND(((([1)×2637.23) − 1280 + ([Width]÷4) )
÷ 60MHz x 10^6) + 442 + [Trigger Pulse Width:10us
~
]
1X2-1Y
80 MHz
1
(Off)
=
ROUND(((([1)×2618.54) − 2618.54 + ([Width]÷2) )
÷ 80MHz x 10^6) + 657 + [Trigger Pulse Width:10us
~
]
2
(On)
=
ROUND(((([1)×5237.09) − 2560 + ([Width]÷2) )
÷ 80MHz x 10^6) + 657 + [Trigger Pulse Width:10us
~
]
60 MHz
1
(Off)
=
ROUND(((([1)×2637.25) − 2637.25 + ([Width]÷2) )
÷ 60MHz x 10^6) + 882 + [Trigger Pulse Width:10us
~
]
2
(On)
=
ROUND(((([1)×5274.49) − 2560 + ([Width]÷2) )
÷ 60MHz x 10^6) + 882 + [Trigger Pulse Width:10us
~
]
Note: When Trigger Overlap is set to OFF, if the trigger pulse is input in shorter period than the period
listed in the above trigger interval, this trigger input may be ignored by the trigger mask.