RAMSES RT 2500 S Universal – User Guide
System:
RT961B2S
Preventive Maintenance
Sub-system
: none
Reference:
PM03
Page:
1/2
Subject:
Replacing the batteries
Periodicity:
every time needed see section II.3.5
Duration:
15 min
18 battery cells, D-Size, Alkaline or Lithium and one 9 V Alkaline Battery (6LR61)
Equipment
Slotted screwdriver
Precaution
Battery pack voltage shall never drop below 6 V (Alkaline) or 17 V (SAFT LSH20 Lithium)
After a long storage period of the unit or before new deployment at sea, it is
recommended to install new battery packs.
Step Action
1.
Prepare and check 18 off D-Size cells and one 9 V Alkaline battery (6LR61).
2.
Open the Release Transponder. Follow the PM02.
3.
Remove the 4 screws from the printed circuit board to access to the batteries
4.
Tilt the instrument to remove used batteries
5.
Insert the new batteries:
Positive (+) terminal first
in the compartments
under
the electronic board and
Negative (-) terminal first
in the compartments
above
the electronic board.
Please respect the sense of fitting of batteries.
Slightly tilt the device to prevent shocks.
6.
Re-install the battery printed circuit board with its four screws
MU – RT961SMk2 – AN - 001- A – June 2010
46
Содержание RAMSES RT 2500 S Universal
Страница 1: ...RAMSES RT 2500 S Universal RT961S Mk2...
Страница 2: ......
Страница 10: ......
Страница 67: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 57...
Страница 68: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 58...
Страница 69: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 59...