RAMSES RT 2500 S Universal – User Guide
VI.5.5
C
ONFIGURING THE
B
LANKING
T
IME AND
T
URN
A
ROUND
T
IME
In this section, you select the blanking and turn around time.
The
Blanking Time
is the time after the transmission of the answer to an interrogation
during which the transponder is deaf.
The
Turn Around Time
is the delay between the beginning of the reception of an
interrogation and the beginning of the transmission of the answer.
Figure 24 –Blanking and Turnaround Time
Procedure
Step Action
1.
Set the tab on the
Blanking Time
ruler at the value to be selected (from 0.4 s to 10.0 s
in 0.1 s steps).
2.
Set the tab on the
Turn Around Time
ruler at the value to be selected (from 0.02 s to
0.2 s in 0.005 steps).
3.
End of procedure.
VI.5.6
C
ONFIGURING THE
A
COUSTIC
T
HRESHOLD
Three different acoustic threshold are available. Depending on your application, you can
adjust the amplitude of the acoustic transmission:
•
Choose 191 dB to optimize the range of the signal
•
Choose 188 dB for average configuration
•
Choose 185 dB to optimize the battery life
Click in the radio button corresponding to the acoustic threshold of your choice.
Figure 25 – Acoustic Threshold
MU – RT961SMk2 – AN - 001- A – June 2010
34
Содержание RAMSES RT 2500 S Universal
Страница 1: ...RAMSES RT 2500 S Universal RT961S Mk2...
Страница 2: ......
Страница 10: ......
Страница 67: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 57...
Страница 68: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 58...
Страница 69: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 59...