RAMSES RT 2500 S Universal – User Guide
System:
RT961B2S
Preventive Maintenance
Sub-system
: none
Reference:
PM02
Page:
3/4
Subject:
Opening the Release Transponder
Periodicity:
every time as needed necessary for changing
batteries
Duration:
5 minutes
Step Action
4.
Open the instrument:
Using the opening /closing ALLEN key (ref FOKIT-B2S), unscrew the central locking
screw located on the lower end plate (anticlockwise) until both end plates are
disconnected from the pressure housing.
(In case of firmly tightened screw the assistance of a second operator may be required
who holds the instrument in place while unlocking the mechanism.)
MU – RT961SMk2 – AN - 001- A – June 2010
44