RAMSES RT 2500 S Universal – User Guide
II.2.3
O
PERATING
M
ODES
The RT912S-Mk2 series unit can be operated in the following operating modes:
•
Remote
control
mode
•
Two interrogation positioning modes, Responder and Transponder modes
•
Pinger
mode
•
Optional Pressure Telemetry mode
II.2.3.1
Remote Control Mode
This mode has priority over all the other modes during the time of reception of the acoustic
remote control command. The characteristics of the remote control mode are:
•
2-states FSK coding, 8 bits words, 100 ms rate
•
Dual sequences commands: ARM code followed with FUNCTION code
ENABLE / DISABLE transponder channels
−
IIF ENABLE (IIF1) & CIF ENABLE (IIF2)
−
IIF ENABLE (IIF1) & CIF DISABLE (IIF2)
−
IIF DISABLE (IIF1) & CIF ENABLE (IIF2)
−
IIF DISABLE (IIF1) & CIF DISABLE (IIF2)
ENABLE / DISABLE responder channels
−
RESPONDER ON IIF(IIF1)
−
RESPONDER ON CIF (IIF2)
RELEASE with CAF acknowledgement and/or switch to Pinger mode
DIAGNOSTIC verticality telemetry and image of battery voltage
PINGER ON/OFF
ON/OFF pressure telemetry, after interrogation transponder/responder (if pressure
sensor option)
PRESSURE acoustical telemetry of the pressure on remote control (if pressure
sensor option)
ACOUSTIC RESET back to the factory configuration
•
CAF acknowledgement of reception and completion of the acoustical remote
commands
•
Compatibility with the TT801 remote control unit and the remote control function of
RAMSES 6000 and USBL-BOX
MU – RT961SMk2 – AN - 001- A – June 2010
8
Содержание RAMSES RT 2500 S Universal
Страница 1: ...RAMSES RT 2500 S Universal RT961S Mk2...
Страница 2: ......
Страница 10: ......
Страница 67: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 57...
Страница 68: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 58...
Страница 69: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 59...