RAMSES RT 2500 S Universal – User Guide
System:
RT961B2S
Preventive Maintenance
Sub-system
: none
Reference:
PM02
Page:
2/4
Subject:
Opening the Release Transponder
Periodicity:
every time as needed necessary for changing
batteries
Duration:
5 minutes
Step Action
2.
Open the hook
:
Using ALLEN 5 mm key, open the hook mechanism by unscrewing the locking screw as
shown (alternatively open the hook using an IXSEA compatible acoustic remote control
unit)
Store the locking screw in a safe place for later re-assembly
3.
Remove the lever arm
:
Using the same ALLEN key, remove the lever in order to gain access to the
opening/closing central screw.
Use of a second identical ALLEN key may be required in case of strongly tightened
screws.
Place lever, central axis, washers (2pcs) and spacers (2pcs) in a safe place for later re-
assembly)
MU – RT961SMk2 – AN - 001- A – June 2010
43