RAMSES RT 2500 S Universal – User Guide
System:
RT961B2S
Preventive Maintenance
Sub-system
: none
Reference:
PM02
Page:
4/4
Subject:
Opening the Release Transponder
Periodicity:
every time as needed necessary for changing
batteries
Duration:
5 minutes
Step Action
5.
Remove the end plates
:
Gently pull on the upper end plate (transducer end) along its axial direction until you can
access the internal transducer connector.
Unplug the transducer head connector (Flat / brown 3 ways plug).
Keep on removing the upper end plate with is integral internal strength member.
Install it on a clean surface, paying special attention to sealing surfaces and O’Ring.
Gently pull on the lower end plate that is integral with motor assembly and electronic /
battery package and remove it from the pressure housing.
Install it on a clean surface, paying special attention to sealing surfaces and O’Ring
Save the pressure cylindrical housing in a secure place. Protect or be sure that its
sealing surfaces are not damaged during the whole operation.
6.
End of Procedure.
MU – RT961SMk2 – AN - 001- A – June 2010
45