RAMSES RT 2500 S Universal – User Guide
II
T
ECHNICAL
S
PECIFICATIONS
II.1
Mechanical Specifications
II.1.1
G
ENERAL
C
HARACTERISTICS
II.1.1.1
“Bottom” Transponder RT961B2S-Mk2
•
Depth rating: 6,000 m
•
Housing
: High mechanical strength and high sea corrosion resistant Super Duplex
Stainless Steel UNS 32550, see section II.1.2
•
B2S (Universal) release hook,
manual rearming and qualified with the following
performances:
Safe Working Load: 2,500 daN
Release Load:
2,500 daN
Test Load:
5,000 daN
•
Optional Pressure Sensor
with acoustical or electrical data transmission
•
Dimensions
: length 757 mm and diameter 166 mm (cage) / 126 mm (tube)
•
Weight:
In air: 27 kg
In water: 20.5 kg
•
Mechanical
interface
Upper cap: protection cage with an anchor load of diameter 25 mm
Lower cap: release hook compatible with release ring 3 t / SWL (A9103234-TR)
•
Operating temperature: -5 °C to +50 °C
•
Storage temperature: -20 °C to +70 °C
MU – RT961SMk2 – AN - 001- A – June 2010