GAPS
-
User Guide
4.4.1.6
Configuring the Hoisting System
1.
Click on the
INSTALLATION > INPUTS
.
2.
Click on
Hoisting System
to have access to the pressure sensor parameters.
3.
In
Input
, select the
Port
between
Serial A, B, C, D
or
Ethernet A, B, C, D
.
4.
In
Protocol
, select
NMEA 183 / PMEVL
and enter a
Timeout
(from 1 to 10 s).
5.
If you have selected
Serial
in step 3, enter the following parameters:
6.
If you have selected
Ethernet
in step 3, enter the following parameters:
7.
Click on
OK
to validate your input data configuration and send this data to the GAPS.
70
MU-GAPS-AN-005-H - November 2019