5.
For a
Serial
link, set up the
Parity
,
Stopbits
,
Standard
and
Baudrate
.
6.
For an
Ethernet
port, select the
Transport Layer
, the
IP address
(in the case of a
TCP
Client Transport Layer
) and the
Port
number.
7.
In
Beacon Selection
enter the
Beacon ID
and its corresponding
TP Code
.
8.
In
Lever Arms
enter the
LV1
,
LV2
and
LV3
values in meters.
9.
Click on
OK
to validate your choices and to send the configuration in the INS.