GAPS
-
User Guide
Table 2 - Wiring of the 23-pin SOURIAU and 21-pin SUBCONN connectors
SUBCONN (GAPS side) SOURIAU (BOX side)
Signal
1
N
Ethernet Rx-
2
X
Ethernet Tx-
3
Not Connected
4
Not Connected , used by iXblue GPS
5
C
Sync PPS–
6
B
Sync IN 1-
7
K
Sync OUT 1–
8
F
Sync OUT 2–
9
Not Connected
10
Not Connected
11
M
Ethernet Rx+
12
Y
Ethernet Tx+
13
Not Connected
14
Not Connected , used by iXblue GPS
15
T
Sync PPS+
16
A
Sync IN+
17
J
Sync OUT 1+
18
U
Sync OUT 2+
19
Not Connected
20
R,W
Power Supply -
21
Z,S
Power
D,E,G
Ethernet and Synchro pairs shield
H,L,P,V
Reserved by iXblue
MU-GAPS-AN-005-H - November 2019
27
Содержание GAPS
Страница 1: ...GAPS Positioning System User Guide...
Страница 2: ......
Страница 22: ...GAPS User Guide Figure 7 HiSys hoisting system 22 MU GAPS AN 005 H November 2019...
Страница 112: ...GAPS User Guide Figure 52 Mobile properties window 112 MU GAPS AN 005 H November 2019...
Страница 228: ...PAGE INTENTIONALLY LEFT BLANK 228 MU GAPS AN 005 H November 2019 GAPS User Guide...
Страница 229: ...GAPS User Guide L GAPS Antenna Mechanical Drawing MU GAPS AN 005 H November 2019 229...
Страница 230: ...GAPS User Guide M Main Cable Repeater Box Mechanical Drawing 230 MU GAPS AN 005 H November 2019...
Страница 231: ...GAPS User Guide N GAPS BOX Mechanical Drawing MU GAPS AN 005 H November 2019 231...
Страница 232: ...GAPS User Guide O Rackable GAPS BOX Mechanical Drawing 232 MU GAPS AN 005 H November 2019...