GAPS
-
User Guide
9.3.4
L
IST AND
M
EANINGS OF
S
TATUS
, W
ARNING AND
E
RRORS
Blue Message
: information,
Orange Message
: warning,
Red Message
: error
SENSOR X (X being UTC/GPS, USBL, GPS, …):
Message
Meaning
Action
Input X - Unusable data
Data received but consistency & integrity tests fail
Check the quality
of serial links
Input X – Data Timeout
Time interval too long
ELECTRONIC:
5 V Analog Supply
Internal electrical problem
Switch off the rack and contact iXblue.
5 V Digital Supply
Internal electrical problem
Switch off the rack and contact iXblue.
12 V Analog Supply
Internal electrical problem
Switch off the rack and contact iXblue.
Clock Updating
System time is not up to date
Configure a UTC sensor.
DSP Communication
Internal problem coming from the sig-
nal processing module.
Switch off the rack and turn it on again. If the
problem remains, contact iXblue.
DSP Configuration
Internal problem coming from the sig-
nal processing module.
Switch off the rack and turn it on again. If the
problem remains, contact iXblue.
Signal Processing
Internal problem coming from the sig-
nal processing module.
Switch off the rack and turn it on again. If the
problem remains, contact iXblue.
DSP Overload
Data processing is overloaded.
Telemetry Overflow
USBL Net. Overflow
Network is overloaded
Reduce number of output protocols and rates
Profile consistency I, II
Too many layers or depth not strictly
increasing
Correct the velocity profile
Transp. consistency I, II
At least 2 transponders with com-
mon interr. Parameters.
Check / correct transp. parameters
Interrogation Overflow
Too many interr. by recurrence.
Lower interrogation number per recurrence.
Transponders Overflow
Too many transp. by recurrence.
Lower number of transp. by recurrence.
Response Overflow
Too many answers in a recurrence.
Lower number of interrogated transp. by
recurrence.
Transp./Int. Overflow
Too many transp. by interrogation.
Reduce number of transp. by interrogation.
Response not supported
Unknown ID of acoustic response
Outputs consistency
Too many output signals.
Reduce number of outputs.
Sensors consistency
Too many sensors in input.
Reduce number of sensors in input.
LBL Base
Not enough transp. for a LBL base.
Add more transponders.
DP Triangulation
Wrong geometry of DP transp. field. Inappropriate DP base for DP operation.
DP Reference
No DP reference transponder.
Add a DP reference transponder.
Timeout Synchro IN PPS
Delay on incoming trigger pulse
MU-GAPS-AN-005-H - November 2019
149
Содержание GAPS
Страница 1: ...GAPS Positioning System User Guide...
Страница 2: ......
Страница 22: ...GAPS User Guide Figure 7 HiSys hoisting system 22 MU GAPS AN 005 H November 2019...
Страница 112: ...GAPS User Guide Figure 52 Mobile properties window 112 MU GAPS AN 005 H November 2019...
Страница 228: ...PAGE INTENTIONALLY LEFT BLANK 228 MU GAPS AN 005 H November 2019 GAPS User Guide...
Страница 229: ...GAPS User Guide L GAPS Antenna Mechanical Drawing MU GAPS AN 005 H November 2019 229...
Страница 230: ...GAPS User Guide M Main Cable Repeater Box Mechanical Drawing 230 MU GAPS AN 005 H November 2019...
Страница 231: ...GAPS User Guide N GAPS BOX Mechanical Drawing MU GAPS AN 005 H November 2019 231...
Страница 232: ...GAPS User Guide O Rackable GAPS BOX Mechanical Drawing 232 MU GAPS AN 005 H November 2019...