GAPS
-
User Guide
TP in sequence telegram
To be sent every 20 s, and if any changes in the sequence. List of active transponders to be
packed. Tp ID 300 is used to identify an LBL position. HAIN positions are not included in the
transponders in sequence telegram.
Example: TP 001/103/ 207/133/300 in use.
Byte #
BCD
INFO.
1
DF
1: SOT
2
03
2: Head byte.
3 - TP in sequence telegram
3
05
3: No of TP in use.
4
00
4: TP 1.
5
01
TP 1
6
01
5: TP 2.
7
03
TP 103
8
02
6: TP 3.
9
07
TP 207
10
01
7: TP 4.
11
33
TP 133
12
03
8: TP 5.
13
00
TP 300
14
00
9: TP 6.
15
00
MU-GAPS-AN-005-H - November 2019