
GAPS
-
User Guide
4.4.1.5
Configuring the Telemetry
Input
1.
Click on the
INSTALLATION > INPUTS
.
2.
Click on
Telemetry
to have access to the specific parameters.
3.
In
Input
, select the
Port
between
Serial A, B, C, D
or
Ethernet A, B, C, D
.
4.
In
Protocol
, select
ITS TELEMETRY
.
5.
If you have selected
Serial
in step 3, enter the following parameters:
6.
If you have selected
Ethernet
in step 3, enter the following parameters:
7.
Click on
OK
to validate your input data configuration and send this data to the GAPS.
The ITS TELEMETRY protocol is produced each time telemetry data is received.
MU-GAPS-AN-005-H - November 2019
69
Содержание GAPS
Страница 1: ...GAPS Positioning System User Guide...
Страница 2: ......
Страница 22: ...GAPS User Guide Figure 7 HiSys hoisting system 22 MU GAPS AN 005 H November 2019...
Страница 112: ...GAPS User Guide Figure 52 Mobile properties window 112 MU GAPS AN 005 H November 2019...
Страница 228: ...PAGE INTENTIONALLY LEFT BLANK 228 MU GAPS AN 005 H November 2019 GAPS User Guide...
Страница 229: ...GAPS User Guide L GAPS Antenna Mechanical Drawing MU GAPS AN 005 H November 2019 229...
Страница 230: ...GAPS User Guide M Main Cable Repeater Box Mechanical Drawing 230 MU GAPS AN 005 H November 2019...
Страница 231: ...GAPS User Guide N GAPS BOX Mechanical Drawing MU GAPS AN 005 H November 2019 231...
Страница 232: ...GAPS User Guide O Rackable GAPS BOX Mechanical Drawing 232 MU GAPS AN 005 H November 2019...