Figure 16: Parallel Alignment with Straight edge
a) Flexible Spacer Couplings: Place a dial indicator on one hub and rotate that hub 360° while tak-
ing readings on the outside diameter of the other hub. When indicator does not deflect more
than 0.051mm | 0.002" total, parallel alignment is achieved. See image below.
Figure 17: Parallel Alignment with Dial Indicator
4.5.1.2 Angular Alignment
1.
Unit is in angular misalignment when the shaft axes are concentric, but not parallel. Shim unit as
required.
a) Flexible Couplings: The normal "gap" (distance between coupling halves) is approximately
3.175mm | 1/8". However, the coupling manufacturer's instructions should be followed. Insert a
"feeler" or taper gauge at 90° intervals on the circumference of the hubs. When the "gap" is
identical within 0.051mm | .002", the unit is in angular alignment. See image below.
Figure 18: Angular Alignment with Flexible Couplings
b) Spider Couplings: The normal "gap" (distance between hub and insert) is approximately
1.588mm | 1/16". However, the coupling manufacturer's instructions should be followed. Check
4.5 Pump-to-driver alignment
22
3175 Installation, Operation and Maintenance Instructions