1. Dam
5. Bedplate
2. Wedges
6. Grout
3. Leave 3/4" to 1-1/2" under bedplate for grout
7. Leave top of foundation rough and wet
before grouting
4. Waste
8. Concrete foundation
Figure 10: Concrete Foundation
The I. D. of the sleeve should be 2 1/2 - 3 times the bolt diameter.
b) Stuff waste around bolts to prevent concrete from entering between bolt and sleeve. Bolts
should be of sufficient length so that they project through the nuts approximately 1/4" after al-
lowance has been made for grouting, bedplate thickness, and nut thickness.
NOTICE:
Remove all dirt from the mounting pads in order to ensure that the correct leveling is achieved.
Failure to do so can result in equipment damage or decreased performance.
3.
Put the unit in place on wedges. The wedges should be placed at four points as shown in the image
below. Some long installations may require additional wedges near the middle of the bedplate.
1. Wedges
2. Foundation
Figure 11: Wedge placement
4.
Disconnect coupling between pump and driver.
4.4 Install Horizontal Pumps
18