A - Feeler Gauge
Figure 52: Feeler Gauge Method
Dial·Indicator Method
1.
Remove one bolt (370C) and thread a pipe or rod in its place. This is to hold a dial indicator as
shown below.
2.
Loosen adjustment bolts and nuts (371A & 423B).
3.
Tighten each bolt (370C) evenly, while slowly rotating the shaft, until impeller just starts to rub
against casing.
4.
Clamp a dial indicator so that the button rests against the end of the shaft, or against the front of
the face of the coupling, and set indicator at zero.
5.
Loosen bolts (370C) about 6 flats.
6.
Be sure that jam nuts on the bolts (371A & 423B) are loose. Tighten bolts (371A & 423B) a flat at
a time, until the dial indicator shows that the shaft has moved 0.38mm | 0.015".
7.
Tighten bolts (370C), then check to be sure all bolts (371A & 423B) are tight. Finally, tighten jam
nuts on bolts (371A & 423B).
6.3 Impeller Clearance Adjustment
54
3175 Installation, Operation and Maintenance Instructions
Содержание Goulds Pumps 3175
Страница 1: ...Installation Operation and Maintenance Instructions 3175 ...