NOTICE:
•
Verify the driver settings before you start any pump. Refer to the applicable drive equip-
ment IOMs and operating procedures.
•
Excessive warm-up rates can cause equipment damage. Ensure the warm-up rate does
not exceed 1.4°C | 2.5°F per minute.
•
The mechanical seal used in an Ex-classified environment must be properly certified.
NOTICE:
You must follow these precautions before you start the pump:
•
Flush and clean the system thoroughly to remove dirt or debris in the pipe system in order
to prevent premature failure at initial startup.
5.2 Pump Bearings
Oil Lubrication
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. Ensure
bearings are properly lubricated prior to startup.
Oil lubricated pumps are not lubricated at the factory. A high quality turbine type oil, with rust and oxida-
tion inhibitors, should be used. Constant level oilers are supplied with most oil lubricated pumps. They
are included in the box of fittings which accompanies the pump. The oiler was adjusted to maintain prop-
er oil level before leaving the factory. The adjustment should be checked in case this setting was distur-
bed. See image below. Check the assembly dimension print for proper location.
1 - Oil level
Figure 35: Oiler
Instructions
1.
Remove adjustment assembly from oiler
2.
Adjust bars to 9/16"
3.
Lock in position
4.
Replace adjustment assembly in oiler
5.2 Pump Bearings