Set motor shaft .002"-.004" low regardless of pumpage temperature.
Figure 14: Pedestal Mounted Units
Figure 15: Casing Mounted Units
Option
Description
Pumpage Temperature
Set
Above Ambient
Motor
Temperature
Shaft
Option
Description
Ambient
0.051mm - 0.102mm | 0.002" - 0.004" Low
38°C | 100°F
0.000mm - 0.051mm | 0.000" - 0.002" High
93°C | 200°F
0.102mm - 0.152mm | 0.004" - 0.006" High
149°C | 300°F
0.203mm - 0.254mm | 0.008" - 0.010" High
204°C | 400°F
0.305mm - 0.356mm | 0.012" - 0.014" High
260°C | 500°F
0.406mm - 0.457mm | 0.016" - 0.018" High
3.
To check the parallel alignment:
a) Flexible Couplings: Place a straight edge across both coupling hubs at four points 90° apart.
The unit will be in parallel alignment when the straight edge rests evenly on both halves. See
image below.
b) "Spider-Insert" Couplings: Place a straight edge across both coupling hubs at four points 90°
apart. The unit will be in parallel alignment when the straight edge rests evenly on both halves.
See image below.
4.5 Pump-to-driver alignment
3175 Installation, Operation and Maintenance Instructions
21