Figure 54: Disassembly
2.
Remove frame foot hold-down bolts.
3.
Remove bolts which hold frame adapter to casing.
4.
Adjust sling tension to support back pull-out assembly.
5.
Slide the back pull-out assembly from the casing. The Model 3175 has jacking bolts to assist disas-
sembly. Screw the jacking bolts into the tapped holes in the frame adapter. Tighten bolts evenly, a
flat at a time, to jack back pull-out assembly from casing
If working space is available to the side of the bedplate, the "pull-out assembly" can be turned per-
pendicular to the bedplate. Replace one pedestal hold-down bolt in bedplate and support the bear-
ing frame flange with blocks. Complete disassembly of the "pull-out" assembly" can be accomplish-
ed on the job site. If preferred, it can be removed to an available work area.
6.
Remove casing gasket.
Figure 55: Pull-out assembly
7.
Remove the impeller screw with 3/4" Allen wrench. Prevent the shaft from rotating by using a
wrench on coupling "flats". Do not lose or damage the impeller screw O-ring.
6.5 Disassemble the Pump