On the basis of the actual current display, the jump response of the controller can be assessed.
Only if the target value is complied with, the set current values for the rated and peak current
correspond to the actual currents.
The values iq_Limit and id_Limit limit the output of the current controller. Here, these values can be
changed. The values should not be set too high or too low. If the values are too high the control is not
correct. The motor is noisy and the motor current is too high. If the values are too low the full power
of the motor cannot be used. In the dialogue box "Motor and Transmission" these two values can be
calculated out of the motor data. However, a manual adjustment of both values can be necessary.
See “Motor and Transmission dialogue box” on page 61