ACSetup programme
Positioning module IMD20, IMD40
A
A
s long as the default password is valid, the users do not notice during the application of the
CSetup programme that a Password is required. If the password differs from the default password,
d to enter the right password in order to permanently store the parameters
e taken into account that the module can be commissioned as usual. It is
however, users are require
in the module. It has to b
just not possible to permanently store the parameters, i.e. the set values are lost, when the module is
switched off.
The Firmware Upda
Use this comma
te / Normal command
nd in order to load a new firmware version into the module. The Hex file (e.g.
irectory as the ACSetup
programme.
The update can only be realised via the serial interface.
All current settings of the drive module parameters are kept during an update. The update process
must not be interrupted (e.g. by switching off the module, interrupting the connection, etc.).
If the update process could not be completed successfully, the drive module is not operational. In this
case, a new update has to be realised with the help of the Firmware Update / via Bootstrap Loader
command.
See “Firmware update” on page 78.
The Firmware Update / via Bootstrap Loader command
Use this command in order to load a new software application into the drive module, if there is no
executable programme.
For this, it is necessary to install the bootstrap jumper on the module (see “Jumper setting” on page
23). After the module is switched on again, the update process can be launched. After a successful
update, this jumper has to be removed again.
Existing parameter values of the drive module are overwritten with default values.
ACCON.HEX) with the new programme version must be in the same d
44