Positioning module IMD20, IMD40
Description of the drive module
Set the "Modes of operation" (606
ter via SDO to the value 3.
ive
0
h
) parame
Send Rece
ID Data
ID Data
602
2F 60 60 00 03 00 00 00 582
60 60 60 00 00 00 00 00
Set the "Control word" (6040
h
) parameter via SDO successively to the values 0x06, 0x07, 0x0F.
(Activate the “Operation Enable” status.
Rece
)
Send
ive
ID Data
ID Data
602
2B 40 60 00 06 00 00 582
0 00 00
00
60 40 60 00 00 0
602
2B 40 60 00 07 00 00
00
582
60 40 60 00 00 00 00 00
602
2B 40 60 00 0F 00 00
00
582
60 40 60 00 00 00 00 00
T
" (6083
h
) parameter is used to set the desired acceleration, e.g. 100000
(
he "Profile acceleration
0x000186A0).
Send Receive
ID Data
ID Data
602
23 83 60 00 A0 86 0
00
1 582
0 00 00 00 00 00
60 83 6
et the "Target velocity" (60FF
h
) parameter, e.g. 50000 (0x0000C350). The motion is launched.
Rece
S
Send
ive
ID Data
ID ata
D
602
23 FF 60 00 50 C3 00
00
582
0 00 00
60 FF 60 00 00 0
Example 2:
Communication:
RS-232
B
19200 Baud
: 20 kBit/s)
N
7 (is only o
tional Can accesses)
ode of operation:
Positioning (profile position mode)
aud rate:
(Can
ode address:
f importance for op
M
37