Positioning module IMD20, IMD40
CanOpen protocol
factor” object. It has to
axis, have to be set.
be taken into account that these two objects of a slave axis, and not of a master
Motor controller write register
utung
Index Sub Name
Typ
Attrib Map Defaultwert Bede
204
Motor Controller
Write Register
RECORD
Writing in registers of the
motor controller
9
2049
00
Number of Entries
Unsigned 8
CONST
N
2
Number of entries
2049
01
Register Offset
Unsigned 8
RW
N
0
Offset write register
2049
02
Register Size
Unsigned 8
RW
N
1
Register length in byte
= 1,2,3,4
2049
03
Data to Register
Unsigned 32
WO
N
0
Data to register
With this object the user can write d
dependence of "Register Size" the first
ata into all write register of the internal motor controller. In
byte or the first 2, 3, or all 4 data bytes of "Data to Register" are
in "Register Offset".
Attrib Map Defaultwert Bedeutung
written with the address
Motor controller read register
Index Sub Name
Typ
204A
Read Regist
Motor Controller
er
RECORD
Reading form registers of
the motor controller
204A
00
Number of Entries
Unsigned 8
CONST
N
2
Number of entries
204A
01
Register Offset
Unsigned 8
RW
N
0
Offset read register
204A
02
Register Size
N
1
Register lenght in byte
,4
Unsigned 8
RW
= 1,2,3
204A
03
Data from Registe
2
RO
0
Data from register
r
Unsigned 3
N
With this
er can read all read register of the internal motor controller. "Data from Register"
can be loa
data of the read regi
in dependence of
" with the first byte or with
the first 2, 3 or all 4 bytes.
Active ta
annel
Index Su
Type
Attrib Map Default
v
Meaning
object the us
de
he
d with t
ster
"Register Size
rget value ch
b Name
alue
2050 00
e comm.
Unsigne
RO
N
Currently set target value
channel
Activ
interface
d 8
This parame
ates which target value channel is currently act
id channel is fixed by means
of the DIP switch on the front side and queri
during boot-up or res
Set bit
ation
Meaning
ter indic
ivated; sa
ed
et.
Design
Bit 0
CAN
Via CAN, data can be read.
Bit 1
RS232
Via RS232, data can be written.
Bit 2
Analogue input (current
controller)
Control word and mode of operation cannot be changed.
Control of the state machine via release signal.
Bit 3
Analogue input (velocity
controller)
See current controller.
123