Description of the drive module
Positioning module IMD20, IMD40
Fault states
If an error occurs, the module switches to the fault state, in which the final stage is switched off. The
n the front side indicate the current error by a blinking sequence.
:
LED
(1)
Description
LEDs o
See EM
Overview or possible fault states
Internal
error
EEC MEC
code
display
1
0x6100
0x00xx
12
Internal software error
2 0x2320
13 Short
circuit
3
0x4210
14
Overtemperature power amplifier
4 0x4220
15 Overtemperature
motor
5
0x5010
16
Internal error of motor controller
6
0x7305
17
Fault Encoder Track A
7
0x7306
18
Fault Encoder Track B
8
0x7307
19
Fault Encoder Track Z
9 0x8100
0x0002
21 CAN
error
10 x7
0
308
22 Deviation of position between the master and the slave is
greater than the maximum admissible value.
11
0x8120
23
Node guarding failed
12
0x5441
24
Negative limit switch active
13
0x5442
25
Positive limit switch active
14
0x5444
26
No enabling signal
16
0x7309
28
Fault in slave axis
17
0x730A
29
Fault in master axis
18 0x6010
31 Watchdog
reset
19
0x3100
32
DC Bus voltage to low
20
0x5114
33
No programming voltage
21
0x5530
34
Error during the deletion / writing of the Flash memory
23
0xFF10
36
Synchronisation error of interpolation
24
0x3110
37
DC Bus Voltage to high
25
0x7400
38
Error hall sensor
26
0x2330
39
I²t current limitation active
(1) 1
st
digit = number of blinking impulses of both LEDs, 2
nd
digit = number of blinking impulses of one LED.
40