Hardware Installations and Upgrades
38
Intel
®
Server Chassis P4000M Service Guide
4. Install the 8x3.5'' Hotswap Hard drives cage. For instructions, see “installing 8x3.5'' Hotswap Hard
Drive Cage Assembly”.
5. Install the front bezel. For instructions, see “Installing the Front Bezel (Pedestal Only)”.
6. Install the air duct if the air duct is removed. For instructions, see “Installing the Airduct”.
7. Install the chassis cover. For instructions, see “Installing the Chassis Cover”.
8. Plug all peripheral devices and the AC power cable into the server.
9. Power up the server.
Removing and Installing 8x2.5'' Hotswap Hard Drive
Cage Assembly
/
NOTE
This procedure applies only to the Intel
®
Server Chassis P4000M family with 8x2.5'' hotswap hard disk
drive cage configuration.
Removing 8x2.5'' Hotswap Hard Drive Cage Assembly
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel (Pedestal
Only)”.
5. Disconnect the power and data cables to the backplane.
6. Use screwdriver to release the hotswap hard drive cage (see letter
A
) from the chassis and remove
the hotswap hard drive cage (see letter
B
).
Figure 60. Removing the 8x2.5
''
HDD Cage Assembly