Hardware Installations and Upgrades
Intel
®
Server Chassis P4000M Service Guide
29
Figure 46. Securing the 2.5” HDD on Fixed HDD Carrier Tray
8. Insert the HDD carrier tray into chassis.
Figure 47. Inserting the HDD Carrier Tray
9. Connect power and data cables on HDD.
10. Install the Fixed HDD EMI shield. For instructions, see “Installing the Fixed HDD EMI Shield”.
11. Install the front bezel. For instructions, see “Installing the Front Bezel”.
12. Install the air duct if the air duct is removed. For instructions, see “Installing the Airduct”
13. Install the chassis cover. For instructions, see “Installing the Chassis Cover”.
14. Plug all peripheral devices and the AC power cable into the server.
15. Power up the server.
Removing and Installing 4x3.5” Hotswap Hard Drive
Cage Assembly
/
NOTE
This procedure applies only to the Intel
®
Server Chassis P4000M family with 4x3.5'' hotswap hard disk
drive cage configuration.
Removing 4x3.5” Hotswap Hard Drive Cage with Backplane
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”.
5. Disconnect the power and data cables to the backplane.