Hardware Installations and Upgrades
26
Intel
®
Server Chassis P4000M Service Guide
Removing and Installing Fixed Hard Drive(s)
/
NOTE
This procedure applies only to the Intel
®
Server Chassis P4000M family with fixed HDD configuration.
Removing Fixed Hard Drive(s)
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”.
5. Remove the Fixed HDD EMI shield. For instructions, see “Removing the Fixed HDD EMI Shield”.
6. Remove power and data cables from the hard drive connectors.
7. Pull out the HDD carrier tray.
Figure 40. Removing Fixed Hard Drives
8. Use screwdriver to release the 3.5” or 2.5” HDD from the carrier tray.
Figure 41. Removing the 3.5” HDD from Fixed HDD tray