Hardware Installations and Upgrades
24
Intel
®
Server Chassis P4000M Service Guide
Installing the Hotswap Fan
1. Observe the safety and ESD precautions at the beginning of this book.
2. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
3. Insert hotswap fan into corresponding chassis slot until it clicks into place.
Figure 37. Installing Hotswap Fan
Removing and Installing the Fixed HDD EMI Shield
/
NOTE
For a rack configuration or chassis on its side, position the chassis hanging over the edge of a table or
workbench before removing the bezel.
This procedure applies only to the Intel
®
Server chassis P4000M family with fixed HDD configuration.
Removing the Fixed HDD EMI Shield
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel. For instructions, see “Removing the front bezel”.
5. Press the clip (see letter
A
) and lift the EMI shield (see letter
B
) and move EMI shield outward from
the chassis.