Hardware Installations and Upgrades
Intel
®
Server Chassis P4000M Service Guide
31
1)
Fit the edges of the EMI shield against the sides of the chassis (see letter
A
).
2)
While pressing the EMI shield, slide the EMI Shield downwards until the latches on the EMI
shield are engaged with the chassis (see letter
B
).
Figure 50. Installing the EMI shield
6. Install the 4x3.5'' Hotswap Hard Drive Cage.
1)
Slide the 4x3.5'' Hotswap Drive Cage into the slot (see letter
A
).
2)
Secure the Hard Drive Cage with the Screw (see letter
B
).
Figure 51. Installing the 4x3.5
''
Hotswap Hard Drive Cage
7. Make the backplane and server board/RAID controller card cable connections. Refer to the
documentation that came with your server board and/or RAID controller card for instructions on
connecting backplane cables to your server board or RAID controller card.
1)
Connect data cables (letter
A
).
2)
Connect an I2C_IN cable (letter
B
).
3)
Connect an SGPIO cable (letter
C
).